This exceptional window has triple glazing for better soundproofing and the most efficient energy efficiency!
A Laminated windows available in several colors
B 5 5/8 ”Novoclimat frame”
C Triple double glazing LOW-E
D
Reinforced modular assembly
– Certification document
(PDF)
E
Stainless steel mechanism
PVR – M – I – 00025 – 0001
Energy
efficiency
Factor
: 1.08 | Solar gain : 0.44 | RE
: 46
1 All-PVC window with fusion-welded corners for better sealing and greater efficiency
2 Multiple air chamber profiles for optimal thermal insulation
3 Triple weatherstripping positioned on the shutter for maximum air and water tightness
4 One-piece, 3-1 / 4 ” or 4-1 / 2 ” deep frame, with or without integrated brickmould, and easy to clean
5 1/2 ” drywall and 3/4 ” wood cavities integrated into the frame
6 Removable interior fiberglass screen with enamelled aluminum frame
7 Water drainage without plug or visible hole
AIRTIGHTNESS
The REGIONAL PVC window has a performance rating of A3 (0.25 (M_ / H) M-1).
A1 : standard required for low rise dwellings as well as for small commercial establishments
A2 : standard required for mid-rise and high-rise dwellings, institutions and commercial establishments
A3 : Required standard for energy efficient institutions and commercial establishments
WATER
TIGHTNESS
The REGIONAL PVC window has the efficiency rating B7 (700 Pa).
B1 : standard required for temperate climatic conditions
B2 : standard required for severe climatic
B3 : standard required for extreme weather conditions
B7 : performance greater than the above-mentioned standards
WIND OVERLOAD RESISTANCE
The REGIONAL PVC window is rated C5 (5.0
kPa).
C1 :
standard required for
adequate resistance to low
overloads
C2 :
standard required for
adequate resistance to medium
overloads
C3 :
standard required for
adequate resistance to heavy
overloads
C5
: performance above the
above-mentioned standards
options
performance
A
Modular or structural
B
Universal Brickmould (1 1/8
”, 2 ”, 4 ”)
with Cavity for Exterior House
Siding
C
Different types and thicknesses
of glazing
D
Tile integrated into the
glazing
E
Interior blowing in wooden plank
covered with PVC or in PVC
plank
F
PVC frame
G
Adapter for aluminum exterior
finish
performance
Product
Casement
/ Awning
Standard
A440-M98
Air
infiltration
A3/F
Water
infiltration
B7
Wind
overload
C4/C5
Break-in
F2
HEAT LOSS FACTOR (U FACTOR)
A
B
C
D
The REGIONAL PVC window has a sufficiently low U factor to be effective even in type D climatic zones.
The U factor indicates the rate of heat loss. The lower the U factor, the slower the transfer from a warm area to a cold area. The US Department of Energy and Natural Resources Canada circumscribe climatic regions to assign minimum performance values for fenestration products.
location
zone
U factor