DISCOVER THE CONTEMPORARY ECONO-PLUS MODEL

This exceptional window has triple glazing for better soundproofing and the most efficient energy efficiency!

A Laminated windows available in several colors

B 5 5/8 ”Novoclimat frame”

C Triple double glazing LOW-E

D Reinforced modular assembly – Certification document (PDF)

E Stainless steel mechanism

PVR – M – I – 00025 – 0001

Energy efficiency

Factor : 1.08 | Solar gain : 0.44 | RE : 46

WE MANUFACTURE ALL OUR WINDOWS ONSITE, CUSTOM-MADE TO YOUR NEEDS.

1 All-PVC window with fusion-welded corners for better sealing and greater efficiency

2 Multiple air chamber profiles for optimal thermal insulation

3 Triple weatherstripping positioned on the shutter for maximum air and water tightness

4 One-piece, 3-1 / 4 ” or 4-1 / 2 ” deep frame, with or without integrated brickmould, and easy to clean

5 1/2 ” drywall and 3/4 ” wood cavities integrated into the frame

6 Removable interior fiberglass screen with enamelled aluminum frame

7 Water drainage without plug or visible hole

AIRTIGHTNESS

The REGIONAL PVC window has a performance rating of A3 (0.25 (M_ / H) M-1).

A1 : standard required for low rise dwellings as well as for small commercial establishments

A2 : standard required for mid-rise and high-rise dwellings, institutions and commercial establishments

A3 : Required standard for energy efficient institutions and commercial establishments

WATER
TIGHTNESS

The REGIONAL PVC window has the efficiency rating B7 (700 Pa).

B1 : standard required for temperate climatic conditions

B2 : standard required for severe climatic

B3 : standard required for extreme weather conditions

B7 : performance greater than the above-mentioned standards

New Project (28)

WIND OVERLOAD RESISTANCE  

The REGIONAL PVC window is rated C5 (5.0 kPa).

C1 : standard required for adequate resistance to low overloads

C2 :
standard required for adequate resistance to medium overloads

C3 :
standard required for adequate resistance to heavy overloads

C5 :
performance above the above-mentioned standards

options

performance

A Modular or structural
B Universal Brickmould (1 1/8 ”, 2 ”, 4 ”) with Cavity for Exterior House Siding
C Different types and thicknesses of glazing
D Tile integrated into the glazing
E Interior blowing in wooden plank covered with PVC or in PVC plank
F PVC frame
G Adapter for aluminum exterior finish

performance

Product                         Casement / Awning
Standard                       A440-M98
Air infiltration                A3/F
Water infiltration           B7
Wind overload               C4/C5
Break-in                        F2

HEAT LOSS FACTOR (U FACTOR)

A

B

C

D

The REGIONAL PVC window has a sufficiently low U factor to be effective even in type D climatic zones.

The U factor indicates the rate of heat loss. The lower the U factor, the slower the transfer from a warm area to a cold area. The US Department of Energy and Natural Resources Canada circumscribe climatic regions to assign minimum performance values for fenestration products.

Geographic
location
Climatic
zone
Maximum
U factor
Gatineau, QC
B
1,80
Montréal, QC
B
1,80
Ottawa ON
B
1,80
Val-D’Or QC
C
1,60
Victoria BC
A
2,00
Inukjuak, QC
D
1,40